SolisStorage EverCore 120kWh / 60kW is an all-in-one C&I energy storage system that integrates hybrid inverter, 314Ah LFP battery and EMS in one pre-integrated, factory-tested package. IP66-rated for outdoor use with patented air cooling, it switches on/off-grid in under 10ms and supports up to 2× PV oversizing.
Solis EverCore C&I Energy Storage System
Leading Features:
• All-in-one C&I storage cabinet with integrated hybrid inverter
• Available in 100kWh, 120kWh and 261kWh configurations
• LFP 3.2V / 314Ah cells, 8000 cell cycle life
• Fire suppression: aerosol, explosion relief valve, audible & visual alarm
• IP55 cabinet + IP66 inverter for outdoor installation
• On-grid & off-grid operation with parallel expansion
Installation Guide
Step-by-step setup of the Solis EverCore commercial battery storage system.
Technical Specifications
| Models | 100kWh-30kW | 100kWh-40kW | 100kWh-50kW | 120kWh-30kW | 120kWh-40kW | 120kWh-50kW | 120kWh-60kW | 261kWh-80kW | 261kWh-100kW | 261kWh-125kW |
| System | ||||||||||
| Rated energy capacity | 100.48 kWh | 120.57 kWh | 261.24 kWh | |||||||
| Max. cycle rate | 0.5 P | |||||||||
| Depth of charge and discharge | 100% | |||||||||
| Dimensions (W × H × D) | 1250 × 2030 × 1540 mm | 1850 × 2230 × 1600 mm | ||||||||
| Dimensions without inverter (W × H × D) | 950 × 2030 × 1540 mm | 1400 × 2230 × 1600 mm | ||||||||
| Weight | 1490 kg (Cabinet) + 73 kg (Inverter) | 1630 kg (Cabinet) + 73kg (Inverter) | 2900 kg (Cabinet) + 170 kg (Inverter) | |||||||
| Operating temperature range | -25 ~ +55°C | |||||||||
| Storage temperature range | 0 ~ +40°C | |||||||||
| Operating humidity range | ≤ 95% (non-condensing) | |||||||||
| Max. operation altitude | 4000 m | |||||||||
| System temperature control mode | Industrial-grade air-conditioning (Cabinet); Air cooling (Pack); Intelligent fan-cooling (Inverter) | |||||||||
| Fire suppression mode | Default: Aerosol, Explosion relief valve, Fire water inlet, Audible and visual alarm; Optional: Flammable gas detector, Explosion relief panel, Explosion-proof exhaust fan | |||||||||
| Ingress protection | IP55 (Cabinet) + IP66 (Inverter) | |||||||||
| Anti-corrosion class (Battery Cabinet / Inverter) | C4/C5 (Optional) / C5 | |||||||||
| Noise (rated operating condition) | 70 dB(A) @ 1 m | 75 dB(A) @ 1 m | ||||||||
| Lightning protection | Type II (AC port), Type II (PV&Battery) | |||||||||
| Protection mode | Anti-islanding protection, residual current detection, insulation resistance detection, AC overcurrent protection, and AC cable connection protection | |||||||||
| Certification standards | IEC62619, IEC61000-6-2/4, IEC62040, IEC63056, IEC62477, UN38.3 | |||||||||
| Battery | ||||||||||
| Cell type | LFP 3.2 V / 314 Ah | |||||||||
| Cell cycle life | 8000 | |||||||||
| System battery configuration | 1P100S | 1P120S | 1P260S | |||||||
| Rated voltage | 320 V | 384 V | 832 V | |||||||
| Operating voltage range | 290 ~ 360 V | 348 ~ 432 V | 754 ~ 936 V | |||||||
| Rated DC current | 157 A | |||||||||
| Number of battery packs | 5 | 6 | 13 | |||||||
| Battery pack capacity / weight | 20.09 kWh / 138 kg | |||||||||
| Inverter | ||||||||||
| Inverter model | S6-EH3P30K-H | S6-EH3P40K-H | S6-EH3P50K-H | S6-EH3P30K-H | S6-EH3P40K-H | S6-EH3P50K-H | S6-EH3P60K-H(21A) | S6-EH3P80K10-NV-YD-H | S6-EH3P100K10-NV-YD-H | S6-EH3P125K10-NV-YD-H |
| Rated output power | 30 kW | 40 kW | 50 kW | 30 kW | 40 kW | 50 kW | 60 kW | 80 kW | 100 kW | 125 kW |
| Max. apparent output power @On-grid | 30 kVA | 40 kVA | 50 kVA | 30 kVA | 40 kVA | 50 kVA | 60 kVA | 80 kVA | 100 kVA | 125 kVA |
| Rated grid voltage | 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V | |||||||||
| Rated grid frequency | 50 Hz / 60 Hz | |||||||||
| Rated output current | 45.6 A / 43.3 A | 60.8 A / 57.7 A | 76 A / 72.2 A | 45.6 A / 43.3 A | 60.8 A / 57.7 A | 76 A / 72.2 A | 91.2 A / 86.6 A | 121.6 A / 115.5 A | 151.9 A / 144.3 A | 189.9 A / 180.4 A |
| Max. apparent output power @Off-grid | 30-60K: 1.5 times of rated power, 10 s; 80-100K: 1.6 times of rated power, 10 s; 125K: 1.4 times of rated power, 10 s | |||||||||
| Back-up switch time | < 10 ms | |||||||||
| Power factor | > 0.99 (0.8 leading - 0.8 lagging) | |||||||||
| THDi / THDv (@linear load) | < 2% / < 3% | |||||||||
| Max. recommended PV input power | 60 kW | 80 kW | 100 kW | 60 kW | 80 kW | 100 kW | 100 kW | 160 kW | 200 kW | 250 kW |
| Max. input voltage | 1000 V | |||||||||
| Rated / Start-up voltage | 600 V / 180 V | |||||||||
| MPPT voltage range | 150 - 850 V | 150 - 950 V | ||||||||
| Full load MPPT voltage range | 600 - 850 V | 550 - 900 V | ||||||||
| Max. input current | 3 × 42 A | 4 × 42 A | 3 × 42 A | 4 × 42 A | 10 × 42 A | |||||
| Max. short circuit current | 3 × 60 A | 4 × 60 A | 3 × 60 A | 4 × 60 A | 10 × 60 A | |||||
| MPPT number / Max. input strings number | 3 / 6 | 4 / 8 | 3 / 6 | 4 / 8 | 10 / 20 | |||||
| Max. parallel quantity (on/off-grid) | 10 | |||||||||