Skip to Content

Solis 5KW Single Phase Hybrid LV Inverter Pro EU

$ 0.00 $ 0.00

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Internal Reference: S6-EH1P5K-L-EU

The Solis S6-EH1P5K-L-EU is a 5kW single-phase energy storage inverter designed for residential PV storage systems, with automatic UPS switching, peak shaving mode, 2 MPPTs, an industry-leading 125A / 6kW max. charge/discharge rating and compatibility with multiple lithium battery brands.

Technical Specifications

Models3K3.6K4.6K5K6K
Input DC (PV side)
Recommended max. PV power4.8 kW5.7 kW7 kW8 kW9.6 kW
Max. input voltage600 V
Rated voltage330 V
Start-up voltage90 V
MPPT voltage range90 - 520 V
Max. input current16 A / 16 A
Max. short circuit current24 A / 24 A
MPPT number / Max. input strings number2 / 2
Battery
Battery typeLi-ion / Lead-acid
Battery voltage range42 - 58 V
Battery capacity50 - 2000 Ah
Max. charge / discharge power3 kW3.6 kW4.6 kW5 kW6 kW
Max. charge / discharge current62.5 A75 A100 A105 A125 A
CommunicationCAN
Output AC (Grid side)
Rated output power3 kW3.6 kW4.6 kW5 kW6 kW
Max. apparent output power3 kVA3.6 kVA4.6 kVA5 kVA6 kVA
Operation phase1/N/PE
Rated grid voltage220 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current13.6 A / 13 A16.4 A / 15.7 A20.9 A / 20 A22.7 A / 21.7 A27.3 A / 26.1 A
Max. output current13.6 A / 13 A16.4 A / 15.7 A20.9 A / 20 A22.7 A / 21.7 A27.3 A / 26.1 A
Power factor> 0.99 (0.8 leading - 0.8 lagging)
THDi< 2%
Input AC (Grid side)
Input voltage range187 - 253 V
Max. input current20 A24.6 A31.4 A32 A40 A
Frequency range45 - 55 Hz / 55 - 65 Hz
Output AC (Back-up)
Rated output power3 kW3.6 kW4.6 kW5 kW6 kW
Max. apparent output power4.2 kVA, 60 s5 kVA, 60 s6.4 kVA, 60 s7 kVA, 60 s8 kVA, 60 s
Back-up switch time< 10 ms
Rated output voltage1/N/PE, 220 V / 230 V
Rated frequency50 Hz / 60 Hz
Max. output current19.1 A22.7 A29.1 A31.8 A36.4 A
THDv (@linear load)< 2%
Efficiency
Max. efficiency> 97.0%> 97.5%
EU efficiency> 96.2%
BAT charged by PV max. efficiency> 94.9%
BAT charged / discharged to AC max. efficiency> 94.33% / 93.51%
Protection
DC reverse-polarity protectionYes
Ground fault monitoringYes
Integrated AFCI (DC arc-fault circuit protection)Yes
Protection class / Over voltage categoryI / II
General Data
Dimensions (W × H × D)405 × 480 × 205 mm
Weight20.3 kg22.4 kg
TopologyHigh frequency isolation (for battery)
Operating ambient temperature range-25 ~ +60°C
Ingress protectionIP66
Cooling conceptNatural cooling
Max. operation altitude4000 m
Grid connection standardG98 or G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, VDE 0126/UTE C 15/VFR:2019, RD 1699/RD 244/UNE 206006/ UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safety / EMC standardIEC/EN 62109-1/-2, EN 61000-6-1/-2/-3/-4
Features
DC connectionMC4 connector
AC connectionQuick connection plug
DisplayLED indicator & Bluetooth + APP
CommunicationRS485, CAN, Optional: Wi-Fi, GPRS, LAN