تخطي للذهاب إلى المحتوى

مرجع داخلي: S6-EH3P50K-H

The Solis S6-EH3P50K-H is a 50kW three-phase high-voltage hybrid inverter tailored for commercial PV storage. It is compatible with 100–280Ah battery modules, supports battery current up to 140A, 160% backup overload, on/off-grid switching under 10ms, 20A PV input current and up to 10 units in parallel.

Solis 50kW Three Phase HV Hybrid Inverter


Leading Features:

• 50kW rated output, up to 96kW usable PV input
• 4 MPPTs / 8 strings, 1000V max. input voltage
• High-voltage Li-ion battery (150~800V), 2 battery inputs, 70A × 2 charge / discharge
• <10ms back-up switch time
• 97.8% max. efficiency, 98.5% PV-to-battery efficiency
• IP66 protection, intelligent redundant fan cooling

Technical Specifications

Models29.9K30K40K50K
Input DC (PV side)
Recommended max. PV array size59.8 kW60 kW80 kW100 kW
Max. usable PV input power59.8 kW60 kW80 kW96 kW
Max. input voltage1000 V
Rated voltage600 V
Start-up voltage180 V
MPPT voltage range150-850 V
Max. input current3*40 A4*40 A
Max. short circuit current3*60 A4*60 A
MPPT number/Max. input strings number3/64/8
Battery
Battery typeLi-ion
Battery voltage range150-800 V
Max. charge / discharge power32.1 kW33 kW44 kW55 kW
Max. charge / discharge current70 A*2
No. of battery inputs2
Max. charge / discharge power of each input32.1 kW33 kW35 kW35 kW
CommunicationCAN/RS485
Output AC (Grid side)
Rated output power29.9 kW30 kW40 kW50 kW
Max. apparent output power29.9 kVA30 kVA40 kVA50 kVA
Rated grid voltage3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current45.4 A / 43.2 A45.6 A / 43.3 A60.8 A / 57.7 A76 A / 72.2 A
Max. output current45.4 A / 43.2 A45.6 A / 43.3 A60.8 A / 57.7 A76 A / 72.2 A
Power factor>0.99 (0.8 leading - 0.8 lagging)
THDi< 3%
Input AC (Grid side)
Max. AC passthrough current90.8 A / 86.4 A91.2 A / 86.6 A121.6 A / 115.4 A152 A / 144.4 A
Rated input voltage3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated input frequency50 Hz / 60 Hz
Input Generator
Max. input power29.9 kW30 kW40 kW50 kW
Rated input current45.4 A / 43.2 A45.6 A / 43.3 A60.8 A / 57.7 A76 A / 72.2 A
Rated input voltage3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated input frequency50 Hz / 60 Hz
Output AC (Back-up)
Rated output power29.9 kW30 kW40 kW50 kW
Max. apparent output power1.6 times of rated power, 2 s
Back-up switch time< 10 ms
Rated output voltage3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated frequency50 Hz / 60 Hz
Rated output current45.4 A / 43.2 A45.6 A / 43.3 A60.8 A / 57.7 A76 A / 72.2 A
THDv (@linear load)< 2%
Efficiency
Max. efficiency97.8%
EU efficiency97.4%
BAT charged by PV Max. efficiency98.5%
BAT charged/discharged to AC Max. efficiency97.5%
Protection
Anti-islanding protectionYes
Output over current protectionYes
Short circuit protectionYes
Integrated DC switchYes
DC reverse-polarity protectionYes
Surge protectionDC Type II / AC Type II
Integrated AFCI 2.0Optional
General Data
Dimensions (W*H*D)530*880*290 mm
Weight73 kg
TopologyTransformerless
Self-consumption (night)<35 W
Operating ambient temperature range-25 ~ +60°C
Relative humidity0-95%
Ingress protectionIP66
Cooling conceptIntelligent redundant fan-cooling
Max. operation altitude4000 m
Grid connection standardG99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1/EN 50549-10, VDE 0126 / UTE C 15/VFR:2019, NTS 631/RD 1699/RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA,PORTARIA Nº 140, DE 21 DE MARÇO DE 2022
Safety/EMC standardIEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011
Features
PV connectionMC4 Quick connection plug
Battery connectionTerminal connector
AC connectionTerminal Block
DisplayLCD + Bluetooth + APP
CommunicationCAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN