تخطي للذهاب إلى المحتوى

مرجع داخلي: S6-EH1P3K-L-PLUS

The Solis S6-EH1P3K-L-PLUS is a 3kW single-phase hybrid inverter for low-voltage batteries (40–60V). It supports PV input up to 160% of rated power, seamless on/off-grid switching in under 10ms, 200% overload for 10s in off-grid mode, compatibility with any 40–60V battery, up to 6 units in parallel and IP66 protection.

Solis 3kW Single Phase LV Hybrid Inverter


Leading Features:

• PV input up to 160% of rated DC power
• Seamless on/off-grid switching in under 10ms
• 200% overload for 10s in off-grid mode
• Compatible with any 40–60V battery
• Up to 6 units in parallel
• IP66 protection for harsh conditions

Technical Specifications

Models3K3.6K5K6K8K
Input DC (PV side)
Recommended max. PV array size6 kW7.2 kW10 kW12 kW16 kW
Max. usable PV input power4.8 kW5.76 kW8 kW9.6 kW12.8 kW
Max. input voltage500 V
Rated voltage330 V
Start-up voltage90 V
MPPT voltage range90-435 V
Max. input current16 A / 16 A32 A / 32 A
Max. short circuit current20 A / 20 A40 A / 40 A
MPPT number/Max. input strings number2/22/4
Battery
Battery typeLi-ion / Lead-acid
Battery voltage range40-60 V
Max. charge / discharge power3 kW3.6 kW5 kW6 kW8 kW
Max. charge / discharge current70 A80 A112 A135 A190 A
CommunicationCAN/RS485
Output AC (Grid side)
Rated output power3 kW3.6 kW5 kW6 kW8 kW
Max. apparent output power3 kVA3.6 kVA5 kVA6 kVA8 kVA
Operation phase1/N/PE
Rated grid voltage220 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current13.7 A / 13.1 A16.4 A / 15.7 A22.8 A / 21.8 A27.3 A / 26.1 A36.4 A / 34.8 A
Max. output current13.7 A / 13.1 A16.4 A / 15.7 A22.8 A / 21.8 A27.3 A / 26.1 A36.4 A / 34.8 A
Power factor>0.99 (0.8 leading - 0.8 lagging)
THDi<2%
Input AC (Grid side)
Input voltage range187-253 V
Max. input current21 A25 A32 A40 A50 A
Frequency range45-55 Hz / 55-65 Hz
Output AC (Back-up)
Rated output power3 kW3.6 kW5 kW6 kW8 kW
Max. apparent output power2 times of rated power, 10 s
Back-up switch time<4 ms
Rated output voltage1/N/PE, 220 V / 230 V
Rated frequency50 Hz / 60 Hz
Rated output current13.7 A / 13.1 A16.4 A / 15.7 A22.8 A / 21.8 A27.3 A / 26.1 A36.4 A / 34.8 A
Max. AC Passthrough current35 A35 A40 A40 A50 A
THDv (@linear load)<2%
Efficiency
Max. efficiency96.2%
EU efficiency94.7%
BAT charged by PV/AC Max. efficiency95.3%/94.5%
BAT discharged to AC Max. efficiency94.9%
Protection
Ground fault monitoringYes
DC reverse-polarity protectionYes
Integrated AFCI 2.0Optional
Protection class/Over voltage categoryI / II (PV and BAT), III (MAINS and BACKUP and GEN)
General Data
Dimensions (W*H*D)335*560*227 mm
Weight21.6 kg22.2 kg
TopologyHigh frequency isolation (for battery)
Operating ambient temperature range-40 ~ +60°C
Ingress protectionIP66
Cooling conceptNatural convectionIntelligent redundant fan-cooling
Max. operation altitude3000 m
Grid connection standardNRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safety/EMC standardIEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
DC connectionMC4 plug (PV port) / Terminal Block (BAT port)
AC connectionTerminal Block
DisplayLCD + Bluetooth + APP
CommunicationRS485, CAN, Optional: Wi-Fi, GPRS, LAN