تخطي للذهاب إلى المحتوى

Solis 2.5KW Single Phase String Inverter

Solis 2.5KW Single Phase String Inverter

$ 0.00 $ 0.00

الشروط والأحكلام
ضمان استرداد الأموال خلال 30 يوم
الشحن خلال 2-3 أيام عمل

مرجع داخلي: S6-GR1P2.5K-S

The Solis S6-GR1P2.5K-S is a 2.5kW single-phase string inverter designed for residential PV plants. It supports export power control, AFCI protection that proactively reduces fire risk, 24-hour load consumption monitoring and adaptive weak-grid operation, all in a compact design for easy installation.

Solis 2.5kW Single Phase String Inverter


Leading Features:

• Designed for residential PV plants
• String current up to 16A
• Supports export power control
• AFCI protection, proactively reduces fire risk
• 24-hour load consumption monitoring
• Adaptive weak grid

Technical Specifications

Model2.5K3K3.6K4K4.6K5K6K
Input DC
Recommended max. PV power3.75 kW4.5 kW5.4 kW6 kW6.9 kW7.5 kW9 kW
Max. input voltage550 V600 V
Rated voltage250 V330 V
Start-up voltage60 V120 V
MPPT voltage range50-450 V90-520 V
Max. input current14 A / 14 A
Max. short circuit current22 A / 22 A
MPPT number/Max. input strings number2/2
Output AC
Rated output power2.5 kW3 kW3.6 kW4 kW4.6 kW5 kW6 kW
Max. apparent output power2.8 kVA3.3 kVA4 kVA4.4 kVA5 kVA5 kVA6 kVA
Max. output power2.8 kW3.3 kW4 kW4.4 kW5 kW5 kW6 kW
Rated grid voltage1/N/PE, 220 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current11.4 A / 10.9 A13.6 A / 13.0 A16.0 A / 15.7 A18.2 A / 17.4 A20.9 A / 20.0 A22.7 A / 21.7 A27.3 A
Max. output current13.3 A15.7 A16.0 A21.0 A23.8 A25.0 A27.3 A
Power factor>0.99 (0.8 leading - 0.8 lagging)
THDi<3%
Efficiency
Max. efficiency97.3%97.3%97.6%97.7%
EU efficiency96.5%96.6%97.1%97.1%
Protection
DC reverse-polarity protectionYes
Short circuit protectionYes
Output over current protectionYes
Surge protectionYes
Grid monitoringYes
Anti-islanding protectionYes
Temperature protectionYes
Integrated AFCI (DC arc-fault circuit protection)Yes (1)
Integrated DC switchOptional
General Data
Dimensions (W*H*D)310*543*160 mm
Weight11 kg11.2 kg12 kg
TopologyTransformerless
Self-consumption (night)<1 W
Operating ambient temperature range-25 ~ +60°C
Relative humidity0-100%
Ingress protectionIP66
Cooling conceptNatural convection
Max. operation altitude4000 m
Grid connection standardG98(2) or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safety/EMC standardIEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3
Features
DC connectionMC4 connector
AC connectionQuick connection plug
DisplayLCD
CommunicationRS485, Optional: Wi-Fi, GPRS