Technical Specifications
| Model | JBL-HYBT-30K-3PH | JBL-HYBT-50K-3PH | JBL-HYBT-100K-3PH | JBL-HYBT-120K-3PH | JBL-HYBT-150K-3PH |
| AC (on-grid) | |||||
| Apparent power | 33kVA | 55kVA | 110kVA | 132kVA | 165kVA |
| Rated power | 30kW | 50kW | 100kW | 120kW | 150kW |
| Rated voltage | 400V | ||||
| Rated current | 43A | 72A | 144A | 173A | 217A |
| AC input | 60kVA | 100kVA | 200kVA | 240kVA | 240kVA |
| Voltage range | 360V-440V | ||||
| Rated frequency | 50/60Hz | ||||
| Frequency range | 45~55/55~65Hz | ||||
| THDi | <3% | ||||
| PF | 0.8 lagging~0.8 leading | ||||
| AC connection | 3/N/PE | ||||
| AC (off-grid) | |||||
| Apparent power | 33kVA | 55kVA | 110kVA | 132kVA | 165kVA |
| Rated power | 30kW | 50kW | 100kW | 120kW | 150kW |
| Rated voltage | 400V | ||||
| Rated current | 43A | 72A | 144A | 173A | 217A |
| THDu | ≤2% linear | ||||
| Rated frequency | 50/60Hz | ||||
| Overload capability | 110%-10 mins 120%-1 min | ||||
| DC (Battery and PV) | |||||
| Max. PV open-circuit voltage | 1000V DC | ||||
| Max. PV power | 45kWp | 75kWp | 150kWp | 180kWp | 225kWp |
| PV MPPT voltage range | 480V-800V DC | ||||
| Battery voltage range at max. charge power | 450V-600V | 500V-600V | 500V-600V | 517V-600V | 500V-600V |
| Battery voltage range | 352V-600V | ||||
| Max. charge power | 45kW | 75kW | 150kW | 180kW | 225kW |
| Max. discharge power | 33kW | 55kW | 110kW | 132kW | 165kW |
| Max. charge current | 100A | 150A | 300A | 350A | 450A |
| Max. discharge current | 93A | 156A | 313A | 374A | 467A |
| General Information | |||||
| Dimension (W/H/D) | 700/1660/600mm | 950/1860/750mm | 1200/1900/800mm | 1200/1900/800mm | 1200/1900/800mm |
| Weight | 355kg | 610kg | 948kg | 1025kg | 1230kg |
| Built-in transformer | Yes | ||||
| Lightning protection | Type II | ||||
| Protection degree | IP20 | ||||
| Noise emission | <75dB(A)@1m | ||||
| Operating temperature | -25 °C~+55 °C | ||||
| Cooling method | Forced-air | ||||
| Relative humidity | 0-95% non-condensing | ||||
| Max. altitude | 6000m (derate over 3000m) | ||||
| Transfer between on/off grid | Automatic≤10ms | ||||
| Standby consumption | <30W | ||||
| Display | Touch screen | ||||
| Communication | RS485/CAN | ||||
| Certificate | CE, MEA, PEA, UKCA, AS 4777.2, EN 61000-6-2:2019, EN 61000-6-4:2019, EN62109-1:2010, EN62109-2:2011, EN 50549-1:2019, IEC62109.1, IEC62109.2, NRS 097-2-1:2017, G99, VDE-AR-N 4105:2018, DIN VDE V 0124-100:2020-06, PSE:2018-12, DEWA | ||||