تخطي للذهاب إلى المحتوى

SolisStorage EverCore 120kWh / 60kW is an all-in-one C&I energy storage system that integrates hybrid inverter, 314Ah LFP battery and EMS in one pre-integrated, factory-tested package. IP66-rated for outdoor use with patented air cooling, it switches on/off-grid in under 10ms and supports up to 2× PV oversizing.

Solis EverCore C&I Energy Storage System


Leading Features:

• All-in-one C&I storage cabinet with integrated hybrid inverter
• Available in 100kWh, 120kWh and 261kWh configurations
• LFP 3.2V / 314Ah cells, 8000 cell cycle life
• Fire suppression: aerosol, explosion relief valve, audible & visual alarm
• IP55 cabinet + IP66 inverter for outdoor installation
• On-grid & off-grid operation with parallel expansion

Installation Guide

Step-by-step setup of the Solis EverCore commercial battery storage system.

Technical Specifications

Models100kWh-30kW100kWh-40kW100kWh-50kW120kWh-30kW120kWh-40kW120kWh-50kW120kWh-60kW261kWh-80kW261kWh-100kW261kWh-125kW
System
Rated energy capacity100.48 kWh120.57 kWh261.24 kWh
Max. cycle rate0.5 P
Depth of charge and discharge100%
Dimensions (W × H × D)1250 × 2030 × 1540 mm1850 × 2230 × 1600 mm
Dimensions without inverter (W × H × D)950 × 2030 × 1540 mm1400 × 2230 × 1600 mm
Weight1490 kg (Cabinet) + 73 kg (Inverter)1630 kg (Cabinet) + 73kg (Inverter)2900 kg (Cabinet) + 170 kg (Inverter)
Operating temperature range-25 ~ +55°C
Storage temperature range0 ~ +40°C
Operating humidity range≤ 95% (non-condensing)
Max. operation altitude4000 m
System temperature control modeIndustrial-grade air-conditioning (Cabinet); Air cooling (Pack); Intelligent fan-cooling (Inverter)
Fire suppression modeDefault: Aerosol, Explosion relief valve, Fire water inlet, Audible and visual alarm; Optional: Flammable gas detector, Explosion relief panel, Explosion-proof exhaust fan
Ingress protectionIP55 (Cabinet) + IP66 (Inverter)
Anti-corrosion class (Battery Cabinet / Inverter)C4/C5 (Optional) / C5
Noise (rated operating condition)70 dB(A) @ 1 m75 dB(A) @ 1 m
Lightning protectionType II (AC port), Type II (PV&Battery)
Protection modeAnti-islanding protection, residual current detection, insulation resistance detection, AC overcurrent protection, and AC cable connection protection
Certification standardsIEC62619, IEC61000-6-2/4, IEC62040, IEC63056, IEC62477, UN38.3
Battery
Cell typeLFP 3.2 V / 314 Ah
Cell cycle life8000
System battery configuration1P100S1P120S1P260S
Rated voltage320 V384 V832 V
Operating voltage range290 ~ 360 V348 ~ 432 V754 ~ 936 V
Rated DC current157 A
Number of battery packs5613
Battery pack capacity / weight20.09 kWh / 138 kg
Inverter
Inverter modelS6-EH3P30K-HS6-EH3P40K-HS6-EH3P50K-HS6-EH3P30K-HS6-EH3P40K-HS6-EH3P50K-HS6-EH3P60K-H(21A)S6-EH3P80K10-NV-YD-HS6-EH3P100K10-NV-YD-HS6-EH3P125K10-NV-YD-H
Rated output power30 kW40 kW50 kW30 kW40 kW50 kW60 kW80 kW100 kW125 kW
Max. apparent output power @On-grid30 kVA40 kVA50 kVA30 kVA40 kVA50 kVA60 kVA80 kVA100 kVA125 kVA
Rated grid voltage3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated grid frequency50 Hz / 60 Hz
Rated output current45.6 A / 43.3 A60.8 A / 57.7 A76 A / 72.2 A45.6 A / 43.3 A60.8 A / 57.7 A76 A / 72.2 A91.2 A / 86.6 A121.6 A / 115.5 A151.9 A / 144.3 A189.9 A / 180.4 A
Max. apparent output power @Off-grid30-60K: 1.5 times of rated power, 10 s; 80-100K: 1.6 times of rated power, 10 s; 125K: 1.4 times of rated power, 10 s
Back-up switch time< 10 ms
Power factor> 0.99 (0.8 leading - 0.8 lagging)
THDi / THDv (@linear load)< 2% / < 3%
Max. recommended PV input power60 kW80 kW100 kW60 kW80 kW100 kW100 kW160 kW200 kW250 kW
Max. input voltage1000 V
Rated / Start-up voltage600 V / 180 V
MPPT voltage range150 - 850 V150 - 950 V
Full load MPPT voltage range600 - 850 V550 - 900 V
Max. input current3 × 42 A4 × 42 A3 × 42 A4 × 42 A10 × 42 A
Max. short circuit current3 × 60 A4 × 60 A3 × 60 A4 × 60 A10 × 60 A
MPPT number / Max. input strings number3 / 64 / 83 / 64 / 810 / 20
Max. parallel quantity (on/off-grid)10